Enotec UNITED STATES
The competitive sales prices for Enotec.
Brand: Enotec
Country: United States
Enotec's products will meet your expectations, high quality, and competitive prices!
Onrion LLC offers import of Enotec's products in the United States.
The products of this brand are widely used in all industrial fields!Products of the brand Enotec offered by Onrion LLC have the company’s guarantee for both quality and origin.Be the best on the market with the help of Onrion LLC and Enotec's products.In order to get an offer with the best price for the brand Enotec, it's only needed to send us your inquiry through e-mail or via the contact form.
Onrion LLC is a Reseller of the Enotec in all of the United States
Our company is not an authorized distributor or representative for Enotec and Enotec brand is the property of its respective owners.

AQUATEC 1000 ,ORDER NO. 20533-111291 ,PROBE TYPE : SME- 53200K10
PROBE SER NO: 11118392KF
ELECTRONIC SERIAL NO: 020411
PROBE TUBE NO: 10.0793H&A
PROBE CELL NO: 110418808MLT
ECO-00200000
Optional
OXITEC Econom~ 02-Grenzwerte:
OXITEC Economy 2x O.. Grenzwerte
ECO-1100105E
OXITEC Economy:
Elektronik mit 50m Kabel
Sonde mit SintermetaU-Filterkopf
ECO-OOO01100
-
FEP-0002
pneumatic cable
FEP-0009
Cable to connect the probe to ATEX
electronic device
FEP-0009-CG2
2 pcs. ATEX EExd IIC cable glands for
FEP-0009 3/4'' NPT
KES - 132000S
Sensor to measure oxygen MLT protection
KES-10004000
Filterkopf Economy mit Sintermetallfilter
KES-10000000
(OXITEC Economy InSitu-O2-Sonde, Mat.: 1.4301/1.4571, Flansch: DN65 PN6)
KES-10003000
OXITEC Economy Sintermetall-Filterkopf
L = 500 mm
Der Filterkopf besteht aus korrosionsbeständigem Edelstahl 1.4571 (316ss) und
besitzt einen Sintermetallfilter.
Die Basissonde besitzt einen Filterkopf mit eine Länge von ca. 500 mm, wodurch
die Messsonde diese Eintauchtiefe erreicht. Größere Eintauchtiefen werden durch
entsprechend längere Filterköpfe erreicht.
Der Filterkopf sitzt im Rauchgaskanal an der Sondenspitze über dem ZrO2-Sensor.
Es handelt sich hierbei um einen Diffusionsfilter, der auch bei hohen Staubbeladungen
nicht verschmutzt. Zur Überprüfung der Messgenauigkeit und bei
Kalibrierung des OXITEC-O2-Analysensystemes wird mit Luft oder einem
beliebigen anderen Prüfgas, mit bekannter O2-Konzentration, das Filtervolumen
gespült und Prüfgas statt Rauchgas wird gemessen.
KES-132090
KES-1321 Keramik-Filterkopf mit Flammensperre und V-Schild
KES-1321000
Replacement complete probe model 132.1 but without filter head and calibration gas valvelength: 385 mm
KEX-50011115A0
Measurement probe , model 5001 KEX , with filter
head blowout and sintered metal filter
INCOLOY (2.4816)
ATEX II 2G Ex d IIC T3 Gb
Cooling pipe Protec (SiSiC) 1000 mm
Gas temperature : up to 1400 ° C,
Probe length 464 mm.
Measuring principle : cell with zirconia
The flue gas pressure : -50 to +50 mbar
Flow rate: 0 to 50 m / s
Ambient temperature : -40 ° C to +80 ° C
Response time : 0,5 s ( at a speed > 10 m / s)
Time T90: 5 s ( at a speed of > 10 m / s)
Material probe : V4A (SS316Ti)
Degree of protection ( junction box ): IP 65
Lower limit of detection: less than 1 ppm O2
Power supply: from the electronic device
Manual valve supply standard gas
Safety distance tube
Mounting flange ANSI 4 "
OXITEC 5000 ECO
OKSİJEN ANALİZÖR CİHAZI
OXITEC 5000 PLU-0025 29329372
Original Spare Part
O2-Sonde KES-5002; Nr. KES-500200000
SIK-132X
SIK-132x Replacement inner probe assembly consisting of: Heater element, Ceramic Heater Support, Thermocouple, Ceramic rod, Signal wire, Ref. air tube, clips and fittings fully tested and assembled ready to slide in to the terminal box end o the probe. Note: the oxygen cell does NOT need removal!
SME-5D2F0030
Electronic device SME 5 in two buildings ATEX II 2G Ex d
IIC T6 Gb, IP 66
Power Supply : 230V/50 Hz, ± 10%
Pneumatic device EExd systems
Sheet steel housing IP 65 with flowmeter
reference and calibration gas manual power
calibration gas instrumentation air ( provided by customer )
Measuring ranges : programmable from ppm to 100 % O2
Accuracy : ± 0.2% of reading
Ambient temperature : -20 ° to +55 ° C
Analog Output: programmable 0/4-20 mA, 500 P
Temperature compensation : e
Calibration in a single section with distance , or at two points with
air and span gas or two points with standard gas
ZO2-0001FOR MODEL KES132X
SENSOR