Enotec OXITEC 5000 ECO in TURKEY

Get the best sales prices in TURKEY for Enotec OXITEC 5000 ECO from Ontrium.

Product: OXITEC 5000 ECO
Brand: Enotec
Country: Turkey
Description : OKSİJEN ANALİZÖR CİHAZI
Condition: New (Unused)

Do you need OXITEC 5000 ECO for a broken machine or new application? Ontrium is the solution you were looking for!

You can get help from our expert regarding sales prices for Enotec - OXITEC 5000 ECO OKSİJEN ANALİZÖR CİHAZI in Turkey.Minimize your expenses with the high quality products of Enotec.Our services will save you time and money which on the other side will help you growth your business!Our company is not a representative of Enotec, but we are selling their products at good prices.Purchase high quality spare parts of Enotec - OXITEC 5000 ECO OKSİJEN ANALİZÖR CİHAZI in Turkey on cheap prices.Our company has proven itself as one of the best and valuable supplier in the world.

Get an offer by sending us an inquiry via e-mail or through our online request form.

Other products from Enotec

AQUATEC 1000 ,ORDER NO. 20533-111291 ,PROBE TYPE : SME- 53200K10 PROBE SER NO: 11118392KF ELECTRONIC SERIAL NO: 020411 PROBE TUBE NO: 10.0793H&A PROBE CELL NO: 110418808MLT
Enotec
ECO-00200000 Optional OXITEC Econom~ 02-Grenzwerte: OXITEC Economy 2x O.. Grenzwerte
Enotec
ECO-1100105E OXITEC Economy: Elektronik mit 50m Kabel Sonde mit SintermetaU-Filterkopf
Enotec
ECO-OOO01100 -
Enotec
FEP-0002 pneumatic cable
Enotec
FEP-0009 Cable to connect the probe to ATEX electronic device
Enotec
FEP-0009-CG2 2 pcs. ATEX EExd IIC cable glands for FEP-0009 3/4'' NPT
Enotec
KES - 132000S Sensor to measure oxygen MLT protection
Enotec
KES-10004000 Filterkopf Economy mit Sintermetallfilter
Enotec
KES-10000000 (OXITEC Economy InSitu-O2-Sonde, Mat.: 1.4301/1.4571, Flansch: DN65 PN6)
Enotec
KES-10003000 OXITEC Economy Sintermetall-Filterkopf L = 500 mm Der Filterkopf besteht aus korrosionsbeständigem Edelstahl 1.4571 (316ss) und besitzt einen Sintermetallfilter. Die Basissonde besitzt einen Filterkopf mit eine Länge von ca. 500 mm, wodurch die Messsonde diese Eintauchtiefe erreicht. Größere Eintauchtiefen werden durch entsprechend längere Filterköpfe erreicht. Der Filterkopf sitzt im Rauchgaskanal an der Sondenspitze über dem ZrO2-Sensor. Es handelt sich hierbei um einen Diffusionsfilter, der auch bei hohen Staubbeladungen nicht verschmutzt. Zur Überprüfung der Messgenauigkeit und bei Kalibrierung des OXITEC-O2-Analysensystemes wird mit Luft oder einem beliebigen anderen Prüfgas, mit bekannter O2-Konzentration, das Filtervolumen gespült und Prüfgas statt Rauchgas wird gemessen.
Enotec
KES-132090 KES-1321 Keramik-Filterkopf mit Flammensperre und V-Schild
Enotec
KES-1321000 Replacement complete probe model 132.1 but without filter head and calibration gas valvelength: 385 mm
Enotec
KEX-50011115A0 Measurement probe , model 5001 KEX , with filter head blowout and sintered metal filter INCOLOY (2.4816) ATEX II 2G Ex d IIC T3 Gb Cooling pipe Protec (SiSiC) 1000 mm Gas temperature : up to 1400 ° C, Probe length 464 mm. Measuring principle : cell with zirconia The flue gas pressure : -50 to +50 mbar Flow rate: 0 to 50 m / s Ambient temperature : -40 ° C to +80 ° C Response time : 0,5 s ( at a speed > 10 m / s) Time T90: 5 s ( at a speed of > 10 m / s) Material probe : V4A (SS316Ti) Degree of protection ( junction box ): IP 65 Lower limit of detection: less than 1 ppm O2 Power supply: from the electronic device Manual valve supply standard gas Safety distance tube Mounting flange ANSI 4 "
Enotec
OXITEC 5000 PLU-0025 29329372 Original Spare Part
Enotec
O2-Sonde KES-5002; Nr. KES-500200000
Enotec
SIK-132X SIK-132x Replacement inner probe assembly consisting of: Heater element, Ceramic Heater Support, Thermocouple, Ceramic rod, Signal wire, Ref. air tube, clips and fittings fully tested and assembled ready to slide in to the terminal box end o the probe. Note: the oxygen cell does NOT need removal!
Enotec
SME-5D2F0030 Electronic device SME 5 in two buildings ATEX II 2G Ex d IIC T6 Gb, IP 66 Power Supply : 230V/50 Hz, ± 10% Pneumatic device EExd systems Sheet steel housing IP 65 with flowmeter reference and calibration gas manual power calibration gas instrumentation air ( provided by customer ) Measuring ranges : programmable from ppm to 100 % O2 Accuracy : ± 0.2% of reading Ambient temperature : -20 ° to +55 ° C Analog Output: programmable 0/4-20 mA, 500 P Temperature compensation : e Calibration in a single section with distance , or at two points with air and span gas or two points with standard gas
Enotec
ZO2-0001FOR MODEL KES132X SENSOR
Enotec
ZO2-0011 Spare MLT oxygen measuring sensor with protective layer with gasket and screws (stainless steel) for KES/KIS probes
Enotec